Product Description
X-Rite i1iSis V2 - Standard Size With OBC

The i1iSis 2 A4/Letter automated chart reader is the ideal instrument to speed up and automate printer profile creation, now supporting M1 measurement standards.

Automate Your Profiling and Calibrating
In high production environments such as photo processing, large format, fine art and high-speed digital printing, frequent measurement of color test charts to keep color management profiles up to date is a must. With the i1iSis 2, this task no longer need be labor-intensive. Simply print the A4 test chart, read it into the i1iSis 2 in to process 1,500 patches in just 8 minutes, and check results. It’s that easy.

The i1iSis 2 is compliant with the latest ISO standards for M-Series measurement illumination conditions, including:
  • M0 (No Filter) where neither substrate nor imaging colorants fluoresces
  • M1 for proper measurement of substrates with optical brightening agents (OBA’s)
  • M2, when there is a desire to eliminate the fluorescing effect from the measurement data.
The i1iSis 2 improves the speed and accuracy of profiling and calibration and helps operators address color drift before it is visible to the human eye. You can even average more than one target and quickly analyze a high volume of charts. Need a larger chart size? Learn about the i1iSis 2 XL A3 chart reader. With the i1iSis 2, spend less time profiling and more time ensuring happy customers!
Read More

X-Rite i1iSis V2 - Standard Size With Obc

Shipped by: digiDirect
SKU
133249
digiDirect Price
$8,499.00
LatitudePay
$8,499.00
AWAITING STOCK
This means item is within an estimated 2 weeks from delivery to digiDirect. For the latest ETA, please click here to contact us.
PAYMENT OPTIONS
0% Interest for 6 Months APPLY NOW!
Earn 8,499 Qantas Points until 30 September 2023
Product Overview

  • Captures full spectral data of an A4 test chart faster for less time spent on press profiling.
  • Assures compliance with new ISO standards for M-Series measurement illumination conditions. Switchable illumination captures M0, M1 and M2 in a single chart measurement cycle.
  • Comes with a built-in vision system with high tolerance for how charts are aligned as they are fed into the system, automatically correcting for misalignment.
  • Accommodates a variety of inks and substrates in any viewing condition using Optical Brightening Agents (OBAs).
  • Complies with GRAcoL 2013, SWOP 2013, and ISO 12647-2, FOGRA 51, FOGRA 52 and the XRGA standard.
+ Read more
X-Rite i1iSis V2 - Standard Size With OBC

The i1iSis 2 A4/Letter automated chart reader is the ideal instrument to speed up and automate printer profile creation, now supporting M1 measurement standards.

Automate Your Profiling and Calibrating
In high production environments such as photo processing, large format, fine art and high-speed digital printing, frequent measurement of color test charts to keep color management profiles up to date is a must. With the i1iSis 2, this task no longer need be labor-intensive. Simply print the A4 test chart, read it into the i1iSis 2 in to process 1,500 patches in just 8 minutes, and check results. It’s that easy.

The i1iSis 2 is compliant with the latest ISO standards for M-Series measurement illumination conditions, including:
  • M0 (No Filter) where neither substrate nor imaging colorants fluoresces
  • M1 for proper measurement of substrates with optical brightening agents (OBA’s)
  • M2, when there is a desire to eliminate the fluorescing effect from the measurement data.
The i1iSis 2 improves the speed and accuracy of profiling and calibration and helps operators address color drift before it is visible to the human eye. You can even average more than one target and quickly analyze a high volume of charts. Need a larger chart size? Learn about the i1iSis 2 XL A3 chart reader. With the i1iSis 2, spend less time profiling and more time ensuring happy customers!
+ Read more
Short Term Repeatability - White 0.1 DE*94 (D50, 2°)
Inter-Instrument Agreement Average 0.4 DE*94 (deviation from X-Rite manufacturing standard at a temperature of 23°C on 12 BCRA tiles (D50, 2°))
Measurement Conditions M0, M1 & M2
Minimal Media Thickness Typical 0.16mm, Range: 0.08 to 0.45mm
Photometric Range 10 nm; Sampling interval 3.5 nm (100 bands)
Spectral Analyzer i1® technology (holographic diffraction grating with diode array)
Spectral Range 380 - 730 nm
Spectral Reporting 10 nm
Aperture Effective measurement aperture during scanning is depending on the patch size
Unit Color Silver/Black
Dimensions  Width 42 cm, depth 16 cm, height 12 cm (16.5 x 6.3 x 4.7 inches)
Weight 3.2 kg (112.9 oz)
Communication Interface USB
Experience Level Intermediate to Advanced
Software Development Kit Available for OEM customers
Sheet Size A4+
Width: 6 to 23 cm (2.4 to 9 in.)
Length: 17 cm to 66 cm (6.7 to 26 in.)
Calibration Automatic on Internal Calibration Reference
Optical Brightener Compensation (OBC) Optical Brightener Compensation (OBC) with i1Profiler software
Connectivity Powered USB port
+ Read more
What’s In The Box
X-Rite i1iSis V2 - Standard Size With OBC
  • i1iSis 2 spectrophotometer
  • Main power cable
  • USB cable
+ Read more
Write Your Own Review
You're reviewing:X-Rite i1iSis V2 - Standard Size With Obc
Your Rating
+ Read more